10. Fault Commands
4200-A2-GB20-00 August 2002
10-37
Example
Retrieve current condition of LT alarm indicators.
RTRV-COND-EQPT:TAMPA:LT:42::;
TAMPA 02-04-20 10:30:23
M 42 COMPLD
/* RTRV-COND-EQPT:TAMPA:LT:42:: */
"LT:MJ,HITEMP,SA,,,,,,Module temperature exceeded limit"
;
Related Commands
None
cond_eqpt As described for command parameters (see Table 10-21,
RTRV-COND-EQPT Command Parameters).
serveff Service effect. Valid values are:
SA: Service affecting
NSA: Not service affecting
[cond_descr] Description of alarm condition.
Table 10-22. RTRV-COND-EQPT Response Parameters (2 of 2)
Parameter Explanation