4. DS1 Facility Commands
4-4
August 2002 4200-A2-GB20-00
Example
Edit circuit 1 on the NT to have a line interface type of T1.
ED-T1:TAMPA:NTT1-1:42:::LINETYPE=T1;
TAMPA 00-11-24 12:30:43
M 42 COMPLD
/* ED-T1:TAMPA:NTT1-1:42:::LINETYPE=T1 */
;
Related Commands
ENT-T1
on page 4-5
RTRV-T1
on page 4-15
Table 4-2. ED-T1 Command Parameters
Parameter Explanation
tid Target NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments unspecified format
errcde Error code (see Appendix A,
Error Codes
)