4. DS1 Facility Commands
4200-A2-GB20-00 August 2002
4-7
Error Response
sid yy-mm-dd hh:mm:ss
M c DENY
/* ENT-T1:[tid]:aid_ds1:[ctag]:::ds1_nblk:[pst] */
aid:ERRCDE=errcde
/* error description */
;
Example
Enter circuit 1 on the NT with a line interface type of T1.
ENT-T1:TAMPA:NTT1:42:::LINETYPE=T1;
TAMPA 01-11-24 12:30:43
M 42 COMPLD
/* ENT-T1:TAMPA:NTT1:42:::LINETYPE=T1 */
;
Related Commands
ED-T1
on page 4-2
RTRV-T1
on page 4-15
Table 4-5. ENT-T1 Response Parameters
Parameter Explanation
tid Target NE identification
yy-mm-dd Year, month, and day
hh:mm:ss Hour, minute, and second
M Message generated in response to an input command
c If provided, ctag; otherwise 0
COMPLD Completed
DENY Input command is denied
/* */ Enclosed are human readable comments unspecified format
errcde Error code (see Appendix A,
Error Codes
)
Vedere la pagina 98